Quality Control and Tests
We design for you, we produce for you.

At Datsan Transformer, we apply routine tests to every product we produce according to IEC60076 or ANSI C57 standards. We improve our testing procedure day by day and equip our laboratory with new devices in order to increase our product quality. Apart from routine tests, we have type tests, such as short circuit mechanical strength tests, performed in accredited laboratories requested by our customers.
In 2020, we established our electronic factory acceptance test infrastructure very quickly due to the Covid-19 pandemic. Our customers can participate in factory acceptance tests online without having to be physically present at our facility for product acceptance.
The following tests are applied to our products:
Routine Tests:
Type Tests:
Temperature rise experiment
Impulse voltage test
Short circuit mechanical strength test
Special Tests:
Noise level measurement,
Zero impedance component measurement
Products
Transformer Tests and Quality Control
Overview
At Datsan, quality is not an afterthought—it is the foundation of our manufacturing process. From incoming raw material inspection to the final performance validation, every transformer undergoes a rigorous series of tests in our high-voltage laboratory. Staffed by experienced engineers and equipped with calibrated instruments, our test bay ensures each unit complies with the latest IEC 60076 standards and meets the specific demands of your project.
Test Categories
Following IEC 60076, we categorize our quality control into three distinct phases to ensure absolute reliability at every level.
Why Choose DATSAN Test Laboratory?
Designed and operated by DATSAN Transformers, our test facility reflects years of engineering experience and international project expertise.
- With over 30 years of transformer manufacturing experience
- ISO/IEC 17025 accredited test procedures
- Computer-controlled measurement systems with Class 0.1 accuracy
- Customer witness testing available upon request
- Complete digital documentation and test reports
- Flexible scheduling for project-specific requirements
DATSAN test reports are accepted by utilities and engineering contractors worldwide.
Engineering & Test Highlights
- Lightning impulse tests up to 200 kV with digital recording
- Temperature rise tests with multi-channel fiber optic sensors
- Precision loss measurement for Ecodesign compliance verification
- Partial discharge measurement for critical insulation assessment
- Short-circuit impedance and dynamic behavior analysis
Each test is engineered to validate performance throughout the transformer's operational lifetime.
Standards & Compliance
All tests are performed in accordance with international standards:
- IEC 60076 (all parts)
- ANSI C57
- ISO 9001 Quality Management System
- ISO 14001 Environmental Management System
- ISO/IEC 17025 Accredited Testing Laboratory
- CE Marking
- Ecodesign Directive (EU) 2019/1783
- IEEE standards where applicable
This ensures global acceptance and regulatory compliance for your projects.
Test Reports & Documentation
- Comprehensive routine test reports for every transformer
- Type test certificates for design verification
- Special test reports with detailed oscillograms and measurements
- Digital archive accessible for future reference
- Customized documentation packages for project requirements
With proper documentation, you have complete traceability and quality proof.
Customization & Technical Support
DATSAN offers customized test programs including:
- Special test sequences for critical applications
- Witness testing with customer engineers
- Additional measurements beyond standard requirements
- Climatic and special condition simulations
Need a customized test protocol or technical clarification?
Our engineering team is ready to support your project and provide a tailored test plan.
Rated Power
Up to 3150 kVA
Standard Test Capacity
Voltage Class
Um ≤ 36 kV
Um ≤ 72.5 kV
Custom configurations available
Test Scope
Routine
Type / Special
Customer selectable
Loss Performance Verification
Technical Test Specifications
Applications
Industrial Facilities
Utility Networks
Renewable Energy
Oil & Gas
Datacenters
Infrastructure Projects
Mining
Commercial Buildings
Marine & Offshore
Menu
Transformer Manufacturer
DATSAN Transformer manufactures oil-immersed distribution and power transformers for industrial, utility, and infrastructure projects worldwide.
Established in 1992, DATSAN combines over 30 years of engineering experience with modern manufacturing and testing capabilities. Our products are designed in accordance with IEC 60076, ANSI C57 and relevant international standards, with Ecodesign-compliant options available upon request.
Contact Us
Datsan Elk. İnş. San. ve Tic. Ltd. Şti.
Address: Kızıltepe Mardin Karayolu 6.km
Kızıltepe, 47400 Mardin / TÜRKİYE
Phone : +90 (482) 215 3188
Fax : +90 (482) 215 1199
English (English)
Turkish (Türkçe)
French (Français)
Arabic (عربي) 